Approach To Estimate The Salivary Flow Using Chromatography

Abstract:

Aim: To develop a simple and safe method to estimate the salivary flow using chromatography paper.

Best services for writing your paper according to Trustpilot

Premium Partner
From $18.00 per page
4,8 / 5
4,80
Writers Experience
4,80
Delivery
4,90
Support
4,70
Price
Recommended Service
From $13.90 per page
4,6 / 5
4,70
Writers Experience
4,70
Delivery
4,60
Support
4,60
Price
From $20.00 per page
4,5 / 5
4,80
Writers Experience
4,50
Delivery
4,40
Support
4,10
Price
* All Partners were chosen among 50+ writing services by our Customer Satisfaction Team

Materials and Method: 30 volunteers participated in the study. The salivary flow rate was estimated using chromatography filter paper and compared with the salivary flow rate per minute. The assay consisted of 3 spots containing starch and potassium iodide per spot on filter paper. Based on the color reaction on the chromatography filter paper the salivary flow rate was estimated.

Results: Pearson’s correlation test showed highly significant negative correlation when the salivary flow rate and the number of colored dots were compared.

Conclusion: This method can be used as a chairside diagnostic aid in estimation of salivary flow

Key words: chromatography filter paper, salivary flow rate, diagnostic aid

A Novel Approach To Estimate The Salivary Flow Using Chromatography Paper

Introduction:

Quantitative and/or qualitative alterations in salivary secretion may lead to localadverse effects like caries, oral mucositis, candidiasis, oral infections, chewing disorders, halitosis and functional adverse effects like dysphagia, hypersalivation(sialorrhea) and hyposalivation(xerostomia).1

Whole saliva (mixed saliva) is a mixture of oral fluids that includes secretions from both the major and minor salivary glands, in addition to several constituents of non-salivary origin, such as gingival crevicular fluid (GCF), expectoratedbronchial and nasal secretions, serum and blood derivatives from oral wounds, bacteria and bacterial products, viruses and fungi, desquamated epithelial cells, other cellular components, and food debris.2

Stimulated saliva is produced on account of some mechanical, gustatory, olfactory, or pharmacological stimulus, contributing to around 80% to 90% of daily salivary production.

In adults the total stimulated salivary flow ranges from 1 to 3 ml/min3whereas the unstimulated salivary flow at rest ranges from 0.25 to 0.35 ml/min.4

Unstimulated salivary flow rate is most affected by the degree of hydration, olfactory stimulation, exposure to light, body positioning, and seasonal and diurnal factors.

There are various methods for the estimation of salivary flow including measurement of glandular salivary flow, resting salivary flow and stimulated salivary flow.

The best two ways to collect whole saliva are the draining method, in which saliva is allowed to drip off the lower lip, and the spitting method, in which the subject expectorates saliva into a test tube.2

This method is time consuming and needs special apparatus like collection tubes or volume meter.

AIM:To evaluatea simple and safe method for the estimation of salivary flow using chromatography paper

MATERIALS AND METHODS:

The study consisted of 30 volunteers comprising of 21 females and 9 males, aged 20-20yrs. The subjects were asked to sit in an upright position with their head bent in a downward position and were asked to collect the saliva in their mouth for 1minute and asked to spit into the collecting test tubes at the end of 1 minute to determine the salivary flow rate/min.

METHOD OF PREPARATION OF FILTER PAPER:

The filter paper for the estimation of salivary flow was prepared according to a method given by Takashi et al using soluble starch, potassium iodideand chromatography paper (70 mm ?21 mm).

4µl of the detection reagent (1% starch solution and 0.3 mol/L potassium iodide solution mixed at a ratio of 3:1) was placed at 3 places on the chromatography paper using a micropipette.

The filter paper was left overnight in a cool dark room and then stored in a light-resistant container until use.

The soluble starch and potassium iodide were dissolved in 0.1 mol/L Tris-HCl buffer the adjusted pH of 7.3.5

METHOD OF PREPERATION OF COLORING REAGENT:

The coloring reagent was prepared from a solution of 31% hydrogen peroxide, ethanol and distilled water at a ratio of 1:7:1.

METHOD OF COLLECTION OF SALIVA:

Subjects were asked to open their mouths and then to lift the tongue.

The tip of the paper was put on the center of the floor of the mouth in the sublingual region.

After 1 minute, the filter paper was taken out and then the coloring reagent (approximately 2µ L) was added dropwise to the spots in the filter paper.

Via the iodine-starch reaction, colorless spots immediately turned blue.

The number of blue spots, including partly colored spots (50%), was grossly counted as an integer.

Based on this we examined the relationship between the number of colored spots and salivary flow rates after insertion of filter paper for 1 minute in the sublingual regions of healthy subjects.5

DISCUSSION:

Common methods for collecting whole saliva include draining, spitting, suction and swab (absorbent) method. In draining method saliva is allowed to drip off the lower lip into a preweighted container or graduated test tube. In spitting method of collection, the saliva is allowed to collect in the floor of the mouth and subjects are asked to spit in the collecting tubes. Whereasin suction method saliva is continuously aspirated from the floor of the mouth into graduated test tubes. In absorbent method pre-weighed cotton rolls, swabs, or gauze are inserted into the opening of the ductal orifices of the salivary glands and reweighed after the collection is completed.The suction and swab method causes some degree of stimulation and variability and thus are not recommended for unstimulated salivary collection whereas swab method is said to be least reliable among the above mentioned methods.6 the otherdisadvantages of these methods are that they are time consuming and need special apparatus like collection tubes or volume meter.

Takashi et al proposed the present method the present assay for salivary flow assessment. The assay system consists of 3 spots 1mm apart containing starch and potassium iodide on the filter paper. Potassium iodide in the spots easily gets displaced with the flow of saliva, in contrast to this starch does not get displaced and gets retained in the original spot. Thus, the colorless spots on the paper not infiltrated with saliva immediately turned blue with the addition of the coloring reagent that contained hydrogen peroxide, whereas the spots on the paper infiltrated with saliva does not show the color. Colored spot is based on the reaction of saliva between potassium iodide and starch in the chromatography paper and the color reaction of iodine-starch to hydrogen peroxide.5

Unstimulated saliva reflects the basal salivary flow rate while stimulated salivarepresents the fuctional reserve of the salivary glands. So the study of unstimulated saliva is useful for the study of salivary gland status.1The presentmethod can be of help in case of elderly patients suffering from xerostomia, in screening tests, post radiation therapy for cancer in elderly patients where salivary flow measurement can play a chair side diagnostic test.

In addition, the method can easily be adjusted to variations in cutoff values and accuracy by changing the number of spots and distance between the spots on the filter paper

With the present method excellent results were obtained between the salivary flow rate and the colored spots with an r value of -1 and p value of 0.0 in healthy individuals. Thus the routine use of this method as a chair side assessment assay for salivary flow would be of benefit to all practicing dentists and patients alike.

You Might Also Like
x

Hi!
I'm Alejandro!

Would you like to get a custom essay? How about receiving a customized one?

Check it out